Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Gut and Liver ; : 817-825, 2020.
Article in English | WPRIM | ID: wpr-833166

ABSTRACT

Background/Aims@#Recently, a three-plane symmetric nee-dle with Franseen geometry was developed for endoscopic ultrasound-guided fine needle biopsy (EUS-FNB). In this ret-rospective study, tissue acquisition per pass was compared between 22-gauge Franseen FNB and standard fine needle aspiration (FNA) needles in patients with solid pancreatic le-sions. @*Methods@#Consecutive patients who underwent EUSFNA or EUS-FNB for solid pancreatic lesions between Octo-ber 2014 and March 2018 were retrospectively studied. The tissue acquisition rate and the diagnostic performance per session, per pass, and at first pass were compared. @*Results@#A total of 663 passes (300 by the FNB needle and 363 by the standard FNA needle) were performed in 154 patients (71 FNB and 83 FNA). The tissue acquisition rate per session and at first pass in the FNB and FNA groups was 100% and 95% (p=0.13) and 87% and 69% (p=0.007), respectively. The multivariate analysis revealed that among the patients, EUS-FNB (odds ratio, 3.07; p=0.01) was associated with a higher first-pass tissue acquisition rate. While the tissue ac-quisition rate reached a plateau after the 4th pass with FNA, it reached a plateau after the 2nd pass with FNB. Among the 129 malignant cases, the histological tissue acquisition rate per session was similar (100% and 94%), but the sensitivity by histology alone per session was higher for FNB than for FNA (93% and 73%, p<0.01). @*Conclusions@#The results of our retrospective analysis indicated that compared with a standard FNA needle, a 22-gauge Franseen FNB needle was associated with a higher first-pass tissue acquisition rate.

2.
Gut and Liver ; : 297-305, 2020.
Article | WPRIM | ID: wpr-833155

ABSTRACT

Endoscopic management of bile duct stones is now the standard of care, but challenges remain with difficult bile duct stones. There are some known factors associated with technically difficult bile duct stones, such as large size and surgically altered anatomy. Endoscopic mechanical lithotripsy is now the standard technique used to remove large bile duct stones, but the efficacy of endoscopic papillary large balloon dilatation (EPLBD) and cholangioscopy with intraductal lithotripsy has been increasingly reported. In patients with surgically altered anatomy, biliary access before stone removal can be technically difficult. Endotherapy using two new endoscopes is now utilized in clinical practice: enteroscopy-assisted endoscopic retrograde cholangiopancreatography and endoscopic ultrasound-guided antegrade treatment. These new approaches can be combined with EPLBD and/or cholangioscopy to remove large bile duct stones from patients with surgically altered anatomy. Since various endoscopic procedures are now available, endoscopists should learn the indications, advantages and disadvantages of each technique for better management of bile duct stones.

3.
Gut and Liver ; : 481-488, 2017.
Article in English | WPRIM | ID: wpr-88949

ABSTRACT

BACKGROUND/AIMS: Endoscopic placement of self-expandable metal stents (SEMSs) has emerged as a palliative treatment for malignant gastric outlet obstruction (GOO). Although covered SEMSs can prevent tumor ingrowth, frequent migration of covered SEMSs may offset their advantages in preventing tumor ingrowth. METHODS: We conducted this multicenter, single-arm, retrospective study at six tertiary referral centers to evaluate the safety and efficacy of a partially covered SEMS with an uncovered large-bore flare at the proximal end as an antimigration system in 41 patients with symptomatic malignant GOO. The primary outcome was clinical success, and the secondary outcomes were technical success, stent dysfunction, adverse events, and survival after stent placement. RESULTS: The technical and clinical success rates were 100% and 95%, respectively. Stent dysfunctions occurred in 17 patients (41%), including stent migration in nine (23%), tumor ingrowth in one (2%), and tumor overgrowth in four (10%). Two patients (5%) developed adverse events: one pancreatitis and one perforation. No procedure-related death was observed. CONCLUSIONS: A novel partially covered SEMS with a large-bore flare proximal end was safe and effective for malignant GOO but failed to prevent stent migration. Further research is warranted to develop a covered SEMS with an optimal antimigration system.


Subject(s)
Humans , Gastric Outlet Obstruction , Palliative Care , Pancreatitis , Retrospective Studies , Self Expandable Metallic Stents , Stents , Tertiary Care Centers
4.
Gut and Liver ; : 142-148, 2017.
Article in English | WPRIM | ID: wpr-85465

ABSTRACT

BACKGROUND/AIMS: In distal malignant biliary obstruction, an antireflux metal stent (ARMS) with a funnel-shaped valve is effective as a reintervention for metal stent occlusion caused by reflux. This study sought to evaluate the feasibility of this ARMS as a first-line metal stent. METHODS: Patients with nonresectable distal malignant biliary obstruction were identified between April and December 2014 at three Japanese tertiary centers. We retrospectively evaluated recurrent biliary obstruction and adverse events after ARMS placement. RESULTS: In total, 20 consecutive patients were included. The most common cause of biliary obstruction was pancreatic cancer (75%). Overall, recurrent biliary obstruction was observed in seven patients (35%), with a median time to recurrent biliary obstruction of 246 days (range, 11 to 246 days). Stent occlusion occurred in five patients (25%), the causes of which were sludge and food impaction in three and two patients, respectively. Stent migration occurred in two patients (10%). The rate of adverse events associated with ARMS was 25%: pancreatitis occurred in three patients, cholecystitis in one and liver abscess in one. No patients experienced non-occlusion cholangitis. CONCLUSIONS: The ARMS as a first-line biliary drainage procedure was feasible. Because the ARMS did not fully prevent stent dysfunction due to reflux, further investigation is warranted.


Subject(s)
Humans , Arm , Asian People , Cholangiopancreatography, Endoscopic Retrograde , Cholangitis , Cholecystitis , Drainage , Liver Abscess , Pancreatic Neoplasms , Pancreatitis , Pilot Projects , Retrospective Studies , Sewage , Stents
5.
Gut and Liver ; : 563-568, 2014.
Article in English | WPRIM | ID: wpr-91769

ABSTRACT

BACKGROUND/AIMS: To determine the nutritional markers important for assessing the degree of pancreatic insufficiency due to chronic pancreatitis in routine clinical practice. METHODS: A total of 137 patients with chronic pancreatitis were followed up for more than 1 year. They were divided into two groups: a pancreatic diabetes mellitus (DM) group, consisting of 47 patients undergoing medical treatment for DM of pancreatic origin, and a nonpancreatic DM group, consisting of 90 other patients (including 86 patients without DM). Serum albumin, prealbumin, total cholesterol, cholinesterase, magnesium, and hemoglobin were compared between the two groups. RESULTS: The total cholesterol was significantly lower in the pancreatic than the nonpancreatic DM group (164 mg/dL vs 183 mg/dL, respectively; p=0.0028). Cholinesterase was significantly lower in the former group (263 U/L vs 291 U/L, respectively; p=0.016). Among the 37 patients with nonalcoholic pancreatitis, there was no difference in the cholinesterase levels between the pancreatic and nonpancreatic (296 U/L vs 304 U/L, respectively; p=0.752) DM groups, although cholesterol levels remained lower in the former (165 mg/dL vs 187 mg/dL, respectively; p=0.052). CONCLUSIONS: Cholinesterase levels are possibly affected by concomitant alcoholic liver injury. The total cholesterol level should be considered when assessing pancreatic insufficiency due to chronic pancreatitis.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Cholesterol/blood , Cholinesterases/blood , Diabetes Mellitus, Type 2/complications , Exocrine Pancreatic Insufficiency/blood , Follow-Up Studies , Liver Cirrhosis, Alcoholic/blood , Nutritional Status , Pancreas/enzymology , Pancreatitis, Alcoholic/blood , Pancreatitis, Chronic/blood , Serum Albumin/analysis
6.
Gut and Liver ; : 725-730, 2013.
Article in English | WPRIM | ID: wpr-209552

ABSTRACT

BACKGROUND/AIMS: Stent migration occurs frequently, but the prevention of complications resulting from covered self-expandable metal stents (C-SEMSs) remains unresolved. We prospectively assessed a newly developed C-SEMS, a modified covered Zeo stent (m-CZS), in terms of its antimigration effect. METHODS: Between February 2010 and January 2011, an m-CZS was inserted into 42 patients (31 initial drainage cases and 11 reintervention cases) at a tertiary referral center and three affiliated hospitals. The laser-cut stent was flared for 1.5 cm at both ends, with a 1 cm raised bank located 1 cm in from each flared end. The main outcome of this study was the rate of stent migration, and secondary outcomes were the rate of recurrent biliary obstruction (RBO), the time to RBO, the frequencies of complications, and overall survival. RESULTS: Of the 31 patients with initial drainage, stent migration occurred in four (12.9%, 95% confidence interval, 5.1% to 29.0%), with a mean time of 131 days. RBO occurred in 18 (58%), with a median time to RBO of 107 days. Following previous C-SEMS migration, seven of 10 patients (70%) did not experience m-CZS migration until death. CONCLUSIONS: m-CZSs with antimigration properties effectively, although not completely, prevented stent migration after stent insertion.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Alloys , Carcinoma/complications , Cholestasis/etiology , Digestive System Neoplasms/complications , Drainage , Equipment Design , Feasibility Studies , Kaplan-Meier Estimate , Lymphatic Metastasis , Prosthesis Failure , Recurrence , Reoperation , Stents/adverse effects , Time Factors
7.
Gut and Liver ; : 399-402, 2012.
Article in English | WPRIM | ID: wpr-119842

ABSTRACT

Patients with pancreatic cancer frequently suffer from both biliary and duodenal obstruction. For such patients, both biliary and duodenal self-expandable metal stent placement is necessary to palliate their symptoms, but it was difficult to cross two metal stents. Recently, endoscopic ultrasonography-guided choledochoduodenostomy (EUS-CDS) was reported to be effective for patients with an inaccessible papilla. We report two cases of pancreatic cancer with both biliary and duodenal obstructions treated successfully with simultaneous duodenal metal stent placement and EUS-CDS. The first case was a 74-year-old man with pancreatic cancer. Duodenoscopy revealed that papilla had been invaded with tumor and duodenography showed severe stenosis in the horizontal portion. After a duodenal uncovered metal stent was placed across the duodenal stricture, EUS-CDS was performed. The second case was a 63-year-old man who previously had a covered metal stent placed for malignant biliary obstruction. After removing the previously placed metal stent, EUS-CDS was performed. Then, a duodenal covered metal stent was placed across the duodenal stenosis. Both patients could tolerate a regular diet and did not suffer from stent occlusion. EUS-CDS combined with duodenal metal stent placement may be an ideal treatment strategy in patients with pancreatic cancer with both duodenal and biliary malignant obstruction.


Subject(s)
Aged , Humans , Middle Aged , Choledochostomy , Constriction, Pathologic , Diet , Duodenal Obstruction , Duodenoscopy , Pancreatic Neoplasms , Stents
SELECTION OF CITATIONS
SEARCH DETAIL